Persluchtfilters met lage drukval
$314.381-19 Piece/Pieces
$298.66≥20Piece/Pieces
betaling Type: | L/C,T/T |
Incoterm: | FOB,CFR,CIF,EXW |
vervoer: | Ocean,Land,Air,Express |
Haven: | Shenzhen,Guangzhou,Shanghai |
Ms. YUKA Filtration
Wat kan ik voor u doen?
$314.381-19 Piece/Pieces
$298.66≥20Piece/Pieces
betaling Type: | L/C,T/T |
Incoterm: | FOB,CFR,CIF,EXW |
vervoer: | Ocean,Land,Air,Express |
Haven: | Shenzhen,Guangzhou,Shanghai |
Model: DT018
merk: YUKA
Working Pressure: 1.0mpa
Element Grade: Pf/Ao/Aa/Ax/Acs/Ar/Aar
Connection Size: Rc1-1/2"
Anti-corrosion Treatment: Inside & Outside
Element Design: No-Touch
Air Filter Housing: 15 Years Lifespan
Woking Temperature Range: 1.5℃-80℃
Element Main Material: Borosilicate Microfiber Glass
Filtration Accuracy: 0.01 Micron, 0.001mg/M³
Flow Rate: 6.0m³/Min
Verkoopeenheden | : | Piece/Pieces |
Pakkettype | : | Karton |
Afbeeldingsvoorbeeld | : |
The file is encrypted. Please fill in the following information to continue accessing it
Wat te doen als de drukval groter wordt?
1. Als het luchtfilterelement verstopt is of de adsorptiecapaciteit te groot is, vervang dan het filterelement.
2. De opname van onzuiverheden is groot en er wordt een voorbehandeling uitgevoerd.
3. Als de filterpatroon water heeft opgehoopt, zoek dan de oorzaak en laat het resterende water weglopen.
4. Het automatische afdruiprek werkt niet, pas het af en repareer of vervang het automatische afdruiprek.
5. De filterinstallatie staat niet waterpas, installeer deze opnieuw.
YUKA-luchtfilterfunctie en voordeel:
①Behuizing 100% getest op lekkage, met een levensduur van 15 jaar. Lage totale kosten voor de eigenaar.
② No-touch Element-ontwerp, gemakkelijk te onderhouden en te repareren.
③Volg de ISO8573.1-2010-norm in klasse 1 filtratieprestaties. Bescherm uw precieze apparatuur en optimaliseer uw productie-efficiëntie.
④Lage drukval, bespaart energie en geld.
⑤ Geschikt voor alle toepassingen en elk type luchtcompressor.
Technische specificatie:
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W (Width) | D (Depth) | H (Height) | A | B | C (clearance for housing) | ||
DT009 | RC1/4" | 5.0 | 0.3 | 10.6 | 80.6 | 69.0 | 224.1 | 24.6 | 173.9 | 50.5 |
DT010 | RC3/8" | 10.0 | 0.6 | 21.2 | 80.6 | 69.0 | 224.1 | 24.6 | 173.9 | 50.5 |
DT011 | RC1/2" | 20.0 | 1.2 | 42.4 | 108.2 | 93.3 | 275.3 | 30.1 | 220.6 | 53.3 |
DT012 | RC3/4" | 25.1 | 1.5 | 53.0 | 108.2 | 93.3 | 275.3 | 30.1 | 220.6 | 53.3 |
DT013 | RC1/2" | 30.1 | 1.8 | 63.5 | 108.2 | 93.3 | 315.3 | 30.1 | 260.6 | 53.3 |
DT014 | RC3/4" | 33.4 | 2.0 | 70.6 | 108.2 | 93.3 | 315.3 | 30.1 | 260.6 | 53.3 |
DT015 | RC3/4" | 46.8 | 2.8 | 98.8 | 133.0 | 113.9 | 399.6 | 40.7 | 291.0 | 59.6 |
DT016 | RC1" | 60.1 | 3.6 | 127.1 | 133.0 | 113.9 | 399.6 | 40.7 | 291.0 | 59.6 |
DT017 | RC1" | 80.2 | 4.8 | 169.4 | 133.0 | 113.9 | 468.4 | 40.7 | 359.8 | 59.6 |
DT018 | RC1-1/2" | 100.2 | 6.0 | 211.8 | 133.0 | 113.9 | 468.4 | 40.7 | 359.8 | 59.6 |
DT019 | RC1-1/2" | 125.3 | 7.5 | 264.8 | 133.0 | 113.9 | 533.7 | 40.7 | 425.3 | 59.6 |
DT020 | RC2" | 200.0 | 12.0 | 424.0 | 170.0 | 158.3 | 783.1 | 52.9 | 623.0 | 59.6 |
DT021 | RC2" | 266.7 | 16.0 | 565.3 | 170.0 | 158.3 | 1065.4 | 52.9 | 945.3 | 59.6 |
DT022 | RC2-1/2" | 316.7 | 19.0 | 671.3 | 170.0 | 158.3 | 1065.4 | 52.9 | 945.3 | 59.6 |
Technical requirements | Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Vervanging en reserveonderdelen
Installatietips van persluchtfilter
1. Reinig de persluchtleidingen en kleppen die zijn aangesloten op de luchtinlaat en -uitlaat van het filter vóór installatie.
2. Gebruik de combinatie van hoofdleidingfiltratie en eindfiltratie om de gaskwaliteit op het gebruikspunt te waarborgen.
3. Bij het installeren moeten de luchtinlaat en -uitlaat van het filter waterpas worden gehouden en moet de riooluitlaat zich onderaan bevinden. In verticale richting moet een bepaalde ruimte worden gereserveerd om het onderhoud van het filter en het vervangen van het filterelement te vergemakkelijken.
4. Het filter van de schroefluchtcompressor moet op een geventileerde en koele plaats worden geïnstalleerd, zo dicht mogelijk bij het luchtpunt, om de invloed van de pijpleiding op de kwaliteit van de gefilterde perslucht te verminderen.
5. Installeer en gebruik binnen het gespecificeerde werkdruk- en werktemperatuurbereik, en installeer alle niveaus van filters in de juiste volgorde volgens de luchtinlaat- en uitlaatinstructies of de richting aangegeven door de pijl, van grove tot fijne installatie. Vermijd zoveel mogelijk bypass tijdens de installatie. Omdat de olie in de lucht wordt omgeleid naar de stroomafwaartse filter en vervolgens aan de binnenwand van de pijpleiding blijft kleven, is het moeilijk om effectieve middelen te vinden om deze te verwijderen.
6. Het filterelement moet regelmatig worden vervangen. Noteer de vervangingstijd zorgvuldig. Het wordt aanbevolen dat de werktijd z one mag niet meer dan 6 000 uur.
7. De afvoertijd van de automatische afvoer is geschikt voor het aftappen van het vloeibare water en het afvoerinterval is afhankelijk van het watergehalte in de pijpleiding;
8. Verschillende soorten persluchtfilters kunnen worden uitgerust met een zwevende bal zonder drukverlies; afvoerkleppen of handmatige kleppen volgens de eisen van de klant.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.